IRC Section R311.7 governs interior and exterior stairways in one- and two-family dwellings. The code ensures safe, consistent stair geometry. All dimensions below are minimums unless stated as maximums. The "7-11 rule" is a common design heuristic: riser height + tread depth should total between 17" and 18" (ideal: 17.5"), and twice the riser plus tread should be 24" to 25".
| Dimension | Requirement | Notes |
|---|---|---|
| Riser Height (max) | 7-3/4" | Difference between largest & smallest riser ≤ 3/8" |
| Tread Depth (min) | 10" | Measured nosing to nosing |
| Headroom (min) | 6'8" | Measured vertically from tread nosing line |
| Stairway Width (min) | 36" | Above handrail height |
| Landing Depth (min) | 36" | Same as stair width |
| Nosing Projection | 3/4" — 1-1/4" | Not required if tread depth ≥ 11" |
| Max Risers per Flight | 12'3" vertical | Landing required between flights |
| Condition | Requirement |
|---|---|
| When required | 4 or more risers |
| Handrail height | 34" — 38" above tread nosing |
| Handrail grip size | Type I: 1-1/4" — 2" perimeter; Type II: larger or shaped |
| Continuous requirement | Full length of stair flight |
| Wall clearance | 1-1/2" minimum from wall |
| End returns | Terminate at newel post or return to wall/floor |
Winder treads must have minimum 6" depth at narrow end and 10" at 12" walkline. Minimum 10" deep treads required for spiral stairs at the 12" walkline with 6-3/4" minimum at narrow end. Spiral stairs must be 26" minimum width. All winder steps within a flight must have identical tread geometry.