Smoke Detector Code — IRC & NFPA 72 Requirements

IRC Section R314 — Smoke Alarms

The International Residential Code requires smoke alarms in specific locations in all new dwelling units and in existing dwellings undergoing renovation. NFPA 72 (National Fire Alarm Code) provides installation standards. The key requirement is that smoke alarms be interconnected so that when one alarms, all alarms in the dwelling sound.

Required Smoke Alarm Locations

LocationRequirementNotes
Each sleeping room1 smoke alarm inside bedroomOr immediately outside if approved locally
Outside sleeping areas1 in immediate vicinity of bedroomsIn hallway/common area serving bedrooms
Each story1 per floor levelIncluding basements (not crawl spaces or uninhabitable attics)
Dwelling unit with split levelsOn each levelIf floor levels differ by ≥ 24", install on upper level

Smoke Alarm Specifications

RequirementSpecification
Power sourceAC primary with battery backup (new construction)
InterconnectionAll alarms must be interconnected (hardwired or wireless)
Mounting — ceiling≥ 4" from wall
Mounting — wall4" — 12" below ceiling
Near ceiling fans≥ 3' from fan blade tips
Near bathrooms≥ 3' from bathroom door (to avoid steam nuisance)
Near kitchen≥ 10' from cooking appliances (or use photoelectric)
StairwaysAt top of stairway on the ceiling

CO Detector Requirements

Carbon monoxide alarms are required outside each sleeping area in dwellings with fuel-burning appliances or attached garages (IRC R315). CO alarms must be listed per UL 2034. New construction requires hardwired CO alarms with battery backup. Combination smoke/CO alarms must be interconnected with the smoke alarm system.