Pipe sizing uses nominal dimensions that may or may not match actual inner or outer diameters depending on the material. Copper uses nominal inside diameter; PEX, PVC, and ABS use nominal trade sizes. Pipe wall thickness is specified by "schedule" — Sch 40 is the most common for standard residential use.
| Nominal Size | OD (inches) | ID (inches) | Wall Thickness | Typical Fixture Served |
|---|---|---|---|---|
| 1/2" | 0.625 | 0.545 | 0.040" | Single fixture, lavatory, sink |
| 3/4" | 0.875 | 0.785 | 0.045" | Shower, tub, hose bib |
| 1" | 1.125 | 1.025 | 0.050" | Branch line, multiple fixtures |
| 1-1/4" | 1.375 | 1.265 | 0.055" | Main supply, groups |
| 1-1/2" | 1.625 | 1.505 | 0.060" | Main supply line |
| 2" | 2.125 | 1.985 | 0.070" | Service entrance |
| Nominal Size | OD (inches) | ID (Sch 40) | Wall | Typical Use |
|---|---|---|---|---|
| 1-1/4" | 1.660 | 1.380 | 0.140" | Lavatory drain |
| 1-1/2" | 1.900 | 1.610 | 0.145" | Lavatory, sink, tub drain |
| 2" | 2.375 | 2.067 | 0.154" | Shower, kitchen sink, washer |
| 3" | 3.500 | 3.068 | 0.216" | Toilet drain, main stack |
| 4" | 4.500 | 4.026 | 0.237" | Building drain, main sewer |
PEX is sized by nominal ID and available in 3/8" through 1". Most residential branch lines use 1/2" PEX; 3/4" is common for trunk lines and manifolds. PEX expands and contracts significantly with temperature — allow 1" of expansion per 100 ft for every 10°F change. Always use the manufacturer's recommended fittings.