R-value measures thermal resistance — higher numbers mean better insulation. The International Energy Conservation Code (IECC) prescribes minimum R-values for each climate zone (1—8, with 1 being hottest and 8 being coldest). These are prescriptive requirements for new construction and major renovations.
| Component | Zone 1—2 | Zone 3 | Zone 4 (excl. Marine) | Zone 4 Marine / 5 | Zone 6—7 | Zone 8 |
|---|---|---|---|---|---|---|
| Attic / Ceiling | R-30 | R-38 | R-38 | R-49 | R-49 | R-60 |
| Wood Frame Wall | R-13 | R-20 | R-20 | R-20+5ci | R-20+5ci | R-20+10ci |
| Floor (over unconditioned) | R-13 | R-19 | R-19 | R-30 | R-30 | R-38 |
| Basement Wall | R-0 | R-5 ci | R-10 ci | R-15 ci | R-15 ci | R-20 ci |
| Slab Edge | R-0 | R-0 | R-10, 2 ft | R-10, 2 ft | R-10, 4 ft | R-15, 4 ft |
| Crawl Space Wall | R-0 | R-5 ci | R-10 ci | R-15 ci | R-15 ci | R-20 ci |
| Insulation Type | R-Value per Inch | Best Use |
|---|---|---|
| Fiberglass batts | R-3.1 — R-3.4 | Framed walls, attics |
| Cellulose (blown) | R-3.2 — R-3.8 | Attics, dense-pack walls |
| Spray foam (open-cell) | R-3.5 — R-3.6 | Walls, attics, rim joists |
| Spray foam (closed-cell) | R-6.0 — R-7.0 | Vaulted ceilings, basements |
| Rigid foam XPS | R-5.0 | Below grade, continuous exterior |
| Rigid foam EPS | R-3.6 — R-4.2 | Below grade, continuous exterior |
| Polyiso (rigid) | R-5.6 — R-6.5 | Exterior wall sheathing, roofing |
| Mineral wool / Rock wool | R-3.7 — R-4.2 | Soundproofing, fire-rated assemblies |