Insulation R-Value Code — IECC 2021 Requirements

Understanding R-Value

R-value measures thermal resistance — higher numbers mean better insulation. The International Energy Conservation Code (IECC) prescribes minimum R-values for each climate zone (1—8, with 1 being hottest and 8 being coldest). These are prescriptive requirements for new construction and major renovations.

IECC Climate Zone R-Value Requirements

ComponentZone 1—2Zone 3Zone 4 (excl. Marine)Zone 4 Marine / 5Zone 6—7Zone 8
Attic / CeilingR-30R-38R-38R-49R-49R-60
Wood Frame WallR-13R-20R-20R-20+5ciR-20+5ciR-20+10ci
Floor (over unconditioned)R-13R-19R-19R-30R-30R-38
Basement WallR-0R-5 ciR-10 ciR-15 ciR-15 ciR-20 ci
Slab EdgeR-0R-0R-10, 2 ftR-10, 2 ftR-10, 4 ftR-15, 4 ft
Crawl Space WallR-0R-5 ciR-10 ciR-15 ciR-15 ciR-20 ci

Common Insulation R-Values Per Inch

Insulation TypeR-Value per InchBest Use
Fiberglass battsR-3.1 — R-3.4Framed walls, attics
Cellulose (blown)R-3.2 — R-3.8Attics, dense-pack walls
Spray foam (open-cell)R-3.5 — R-3.6Walls, attics, rim joists
Spray foam (closed-cell)R-6.0 — R-7.0Vaulted ceilings, basements
Rigid foam XPSR-5.0Below grade, continuous exterior
Rigid foam EPSR-3.6 — R-4.2Below grade, continuous exterior
Polyiso (rigid)R-5.6 — R-6.5Exterior wall sheathing, roofing
Mineral wool / Rock woolR-3.7 — R-4.2Soundproofing, fire-rated assemblies