A Ground-Fault Circuit Interrupter monitors the current flowing in the hot and neutral conductors. If there's an imbalance of 4—6 milliamps (indicating current leaking to ground through a person or object), the GFCI trips within 1/30th of a second. GFCIs are available as circuit-breaker types (in the panel), receptacle types, and portable types.
| Location | NEC Section | Details |
|---|---|---|
| Bathrooms | 210.8(A)(1) | All 125V receptacles, all bathroom receptacles |
| Garages & accessory buildings | 210.8(A)(2) | All 125V receptacles (with exceptions for dedicated appliances) |
| Outdoors | 210.8(A)(3) | All 125V receptacles, must be WR type |
| Crawl spaces (at or below grade) | 210.8(A)(4) | All 125V receptacles |
| Unfinished basements | 210.8(A)(5) | All 125V receptacles (with exceptions) |
| Kitchen countertops | 210.8(A)(6) | All 125V receptacles serving countertop surfaces |
| Within 6' of sink | 210.8(A)(7) | Any sink — kitchen, laundry, bar, utility |
| Boat hoists | 210.8(C) | All 125V—250V receptacles |
| Laundry areas | 210.8(A)(10) | All 125V receptacles (since 2017 NEC) |
| Damp/wet bar sinks | 210.8(A)(9) | All 125V receptacles serving wet bar areas |
| NEC Edition | New GFCI Requirements Added |
|---|---|
| 2020/2023 | All 125V—250V receptacles in kitchens, GFCI for all basement receptacles |
| 2017 | Laundry area receptacles, all kitchen branch circuits |
| 2014 | Dishwashers (hardwired or cord-connected) |
| 2011 | Garage receptacles (all, not just accessible) |
| 2008 | All kitchen counter receptacles (previously only within 6' of sink) |