Electrical Outlet Code — NEC Receptacle Requirements

NEC 210.52 — Dwelling Unit Receptacle Outlets

The National Electrical Code (NEC) Article 210.52 specifies minimum receptacle outlet locations and spacing for habitable rooms, kitchens, bathrooms, and other areas. The primary rule is the "6-foot/12-foot rule": no point along a wall line should be more than 6 feet horizontally from a receptacle outlet, meaning receptacles are spaced no more than 12 feet apart along the wall.

General Room Receptacle Spacing

LocationRequirementNotes
Any wall ≥ 2' wideAt least 1 receptacleCounts toward 6' rule
Wall spacing≤ 12' apart (6' from any point)Measured along wall line, including corners
Floor receptaclesCounts if within 18" of wallMust be listed for floor use
Countertop (kitchen)≤ 24" spacing, no point > 24" from outletAll countertops ≥ 12" wide
Peninsula/IslandAt least 1 receptacleIf long dimension ≥ 24" and short ≥ 12"

Specific Room Requirements

RoomMinimum ReceptaclesCircuit Requirements
Kitchen2+ 20A small appliance circuitsGFCI required, no other rooms on circuit
Bathroom1+ within 3' of basin edgeGFCI required, 20A circuit (bathroom only or whole-house)
Laundry1+ on 20A circuitGFCI required (since 2017 NEC), dedicated
Hallway (≥ 10')At least 1Standard spacing rules apply
Outdoors (front & back)1+ each exterior gradeGFCI required, WR (weather-resistant)
Garage1+ per bayGFCI required

AFCI & GFCI Protection

AFCI (Arc-Fault Circuit Interrupter): Required in virtually all habitable rooms per NEC 2023: living rooms, bedrooms, dining rooms, kitchens, laundry, hallways, and similar areas on 120V 15A/20A circuits. GFCI (Ground-Fault Circuit Interrupter): Required in bathrooms, kitchens, garages, crawl spaces, unfinished basements, outdoors, laundry areas, and within 6' of any sink.