Deck Code Requirements — IRC 2021 Reference

Overview

Residential deck construction is governed by the International Residential Code (IRC) Section R507. This section was completely rewritten in the 2015 IRC and updated through 2021. Local jurisdictions may have amendments, but these tables represent the baseline prescriptive code for decks up to 40 square feet above grade and supporting up to 40 psf live load plus 10 psf dead load.

Joist Span Requirements

Joist Size12" OC Span16" OC Span24" OC Span
2×6 (Southern Pine #2)9'11"9'0"7'7"
2×8 (Southern Pine #2)13'1"11'10"9'8"
2×10 (Southern Pine #2)16'2"14'0"11'5"
2×12 (Southern Pine #2)18'0"16'2"13'6"

Ledger Attachment

Joist SpanFastener SpacingFastener Type
≤ 8'24" oc1/2" lag screw or bolt
8'—14'16" oc1/2" lag screw or bolt
14'—18'12" oc1/2" lag screw or bolt

Guardrail & Stair Requirements

RequirementSpecification
Guard required when deck surface> 30" above grade
Guardrail height (residential)36" minimum
Baluster spacing≤ 4" sphere cannot pass through
Stair width36" minimum
Riser height7-3/4" maximum
Tread depth10" minimum
Handrail height34" — 38" above tread nosing
Footing depthBelow frost line (min 12" dia × 6" thick)