Electrical
1. Watts to Amps
Watts
Voltage
120
240
480
Amps:
-
2. Amps to Watts
Amps
Voltage
120
240
480
Watts:
-
3. kVA to Amps
kVA
Voltage
Phase
1
3
Amps:
-
4. HP to Amps
HP
Voltage
Phase
1
3
Amps:
-
5. Motor kVA
HP
Efficiency %
Power Factor
kVA:
-
6. Power Factor Correction
kW
Current PF
Desired PF
kVAR Needed:
-
7. Transformer kVA
Primary V
Secondary V
Load Amps
kVA:
-
| Turns Ratio:
-
8. Transformer Primary Current
kVA
Voltage
Phase
3
1
Primary Amps:
-
9. Transformer Secondary Current
kVA
Voltage
Phase
3
1
Secondary Amps:
-
10. Voltage Drop 1-Phase
Amps
Distance (ft)
Wire Size
14
12
10
8
6
4
2
1/0
2/0
3/0
4/0
Voltage
120
240
Voltage Drop:
-
11. Voltage Drop 3-Phase
Amps
Distance (ft)
Wire Size
14
12
10
8
6
4
2
1/0
2/0
3/0
4/0
Voltage
208
480
Voltage Drop:
-
12. Wire Size from Amps
Amps
Material
Copper
Aluminum
Temp Rating
60°C (140°F)
75°C (167°F)
90°C (194°F)
Recommended AWG:
-
13. Wire Ampacity
AWG
14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
Material
Copper
Aluminum
Temp Rating
75°C (167°F)
60°C (140°F)
90°C (194°F)
Ampacity:
-
14. Conduit Fill EMT
Conduit Size
1/2
3/4
1
1-1/4
1-1/2
2
Wire AWG
14
12
10
8
6
4
Wire Count
Fill %:
-
| Max Wires:
-
15. Conduit Fill PVC
Conduit Size
1/2
3/4
1
1-1/4
1-1/2
2
Wire AWG
14
12
10
8
6
4
Wire Count
Fill %:
-
| Max Wires:
-
16. Conduit Fill RMC
Conduit Size
1/2
3/4
1
1-1/4
1-1/2
2
Wire AWG
14
12
10
8
6
4
Wire Count
Fill %:
-
| Max Wires:
-
17. Box Fill
Box Volume (cu in)
Wire Count (each)
Wire AWG
14
12
10
8
Device Count
Fill Volume:
-
18. Cable Tray Fill
Tray Width (in)
Cable Diameter (in)
Cable Count
Fill %:
-
| Max Cables:
-
19. Ground Wire Size
Service / OCPD Amps
Ground Wire AWG (Cu):
-
| (Al):
-
20. Ground Rod Resistance
Rod Length (ft)
Soil Resistivity (Ω-m)
Rod Diameter (in)
Resistance:
-
21. Panel Load Residential
Sq Ft
Small Appl. Circuits
Laundry Circuits
Service Amps:
-
| Panel Size:
-
22. Panel Load Commercial
Sq Ft
Receptacle Load (VA)
Equipment Load (VA)
Total VA:
-
| Amps @ 208V/3ph:
-
23. Subpanel Feeder Sizing
Subpanel Amps
Distance (ft)
Max VD%
Recommended Feeder Cu:
-
| Al:
-
24. Short Circuit Current
Transformer kVA
Impedance %
Voltage (L-L)
SCC:
-
| SCC @ Secondary:
-
25. Arc Flash Boundary
Voltage (kV)
Bolted Fault (kA)
Clearing Time (s)
Arc Flash Boundary:
-
| Incident Energy:
-
26. Motor Overload Setting
FLA
Service Factor
Overload Setting:
-
27. Motor Branch Circuit Breaker
FLA
Motor Type
Squirrel Cage
Wound Rotor
Synchronous
DC
Max Breaker:
-
| Standard Size:
-
28. Motor Starter NEMA Size
HP
Voltage
208
240
480
NEMA Size:
-
| Max HP:
-
29. Capacitor kVAR
Capacitance (µF)
Voltage
Frequency
60
50
kVAR:
-
| Reactance:
-
30. Capacitor Current
kVAR
Voltage
Phase
3
1
Capacitor Amps:
-
31. Lumens Per Square Foot
Room Sq Ft
Desired Foot-Candles
Light Loss Factor
Total Lumens:
-
| Lumens/Sq Ft:
-
32. Fixture Count
Room Sq Ft
Fixture Lumens
Target Foot-Candles
LLF
Fixtures Needed:
-
33. Fixture Spacing
Room Length (ft)
Room Width (ft)
Mounting Height (ft)
Spacing Ratio
Max Spacing:
-
| Rows:
-
| Columns:
-
34. Lighting Load NEC
Sq Ft
Building Type
Dwelling
Office
Retail
Warehouse
Voltage
120
277
VA:
-
| Amps:
-
35. Exit Sign Battery Load
Exit Signs Count
Watts per Sign
Runtime (hours)
Total Watts:
-
| Battery Wh Needed:
-
36. Daylight Area
Window Area (sq ft)
Visible Transmittance
Room Depth (ft)
Daylight Zone Area:
-
| Effective Light:
-
37. LED Driver Sizing
LED Watts
LED Voltage
Oversize Factor %
Driver Size:
-
| Output Amps:
-
38. Lumen Maintenance
Initial Lumens
L70 Hours
Operating Hours Used
Remaining Lumens:
-
| Depreciation:
-
39. Parking Lot Lighting
Lot Area (sq ft)
Required FC
Pole Height (ft)
Fixture Lumens
Poles Needed:
-
| Coverage per Pole:
-
40. Lighting Power Density
Total Fixture Watts
Room Sq Ft
LPD:
-
| ASHRAE 90.1 Limit:
-
41. Solar Panel Count
Annual kWh Usage
Panel Wattage
Sun Hours/Day
System Efficiency %
Panels Needed:
-
| System kW:
-
42. Solar Inverter Sizing
Array kW
DC/AC Ratio
Inverter Size:
-
| Max DC Input:
-
43. Battery Capacity
Daily kWh Usage
Days Autonomy
Battery Voltage
12
24
48
Depth of Discharge %
Battery Bank Ah:
-
| kWh Capacity:
-
44. Charge Controller Sizing
Array kW
Battery Voltage
12
24
48
Safety Factor %
Charge Controller Amps:
-
45. Solar Payback Period
System Cost ($)
Annual Savings ($)
Tax Credit %
Net Cost:
-
| Payback:
-
46. PV String Sizing
Module Voc
Module Vmp
Inverter Vmax
Inverter Vmp Range
Max Modules/String:
-
| Optimal:
-
47. Solar Irradiance to Power
Panel kWp
Irradiance (W/m²)
Temperature Loss %
Power Output:
-
48. Solar Cable Sizing
Array Amps (Isc)
Distance (ft, 1-way)
Max VD%
System Voltage
Min Cable AWG:
-
49. Solar Panel Tilt Angle
Latitude (degrees)
Season
Year-Round
Winter
Summer
Optimal Tilt:
-
50. Solar ROI
System Cost ($)
Annual Savings ($)
System Life (yrs)
Total Savings:
-
| ROI:
-
51. Grounding Electrode Conductor
Service Conductor Size
2
1
1/0
2/0
3/0
4/0
250
350
500
Material
Copper
Aluminum
GEC Size:
-
52. Equipotential Bonding Grid
Pool Perimeter (ft)
Grid Spacing (ft)
#8 Cu Wire Needed:
-
53. GFCI Trip Current
Leakage Current (mA)
GFCI Class
Class A (5-6mA)
Class C (20mA)
Will Trip:
-
| Margin:
-
54. AFCI Protection Required?
Voltage
Room Type
Bedroom
Living Room
Kitchen
Garage
Bathroom
AFCI Required?
-
55. Surge Arrester Rating
Service Voltage
Phase
1
3
Exposure Level
Low
Medium
High
SPD kA Rating:
-
| MCOV:
-
56. Touch Potential
Fault Current (A)
Ground Resistance (Ω)
Body Resistance (Ω)
Touch Voltage:
-
| Body Current:
-
57. Ground Fault Protection
Service Amps
Voltage
GFP Required?
-
| Pickup Setting:
-
58. Step Potential
Soil Resistivity (Ω-m)
Fault Current (A)
Step Distance (m)
Step Voltage:
-
59. Isolation Transformer Grounding
Secondary Voltage
kVA
System Bonding Jumper:
-
| Grounded Conductor:
-
60. Arc Fault Current Minimum
Source Voltage
Arc Gap (mm)
Conductor Spacing (mm)
Min Arc Current:
-
61. Bus Duct Ampacity
Bus Cross Section (sq in)
Material
Copper
Aluminum
Bus Configuration
Indoor
Outdoor
Estimated Ampacity:
-
62. Cable Derating - Ambient Temp
Base Ampacity
Ambient Temp (°F)
Temp Rating
75C
90C
Derated Amps:
-
| Correction Factor:
-
63. Cable Derating - Conduit Fill
Base Ampacity
Current-Carrying Conductors
Derated Amps:
-
| Derating Factor:
-
64. Parallel Conductors
Total Amps
Sets (per phase)
Material
Copper
Aluminum
Amps per Conductor:
-
| Min Size:
-
65. Neutral Sizing
Phase Conductor AWG
4/0
3/0
2/0
1/0
2
4
6
Load Type
Balanced
Harmonic Loads
Neutral Size:
-
66. Cable Pulling Tension
Cable Weight (lbs/ft)
Length (ft)
Bends Count
Friction Coeff
Pulling Tension:
-
| Max Allowed:
-
67. Cable Tray Ampacity Derating
Base Ampacity
Cables in Tray
Tray Cover
No Cover
Covered
Derated Ampacity:
-
68. Shielded Cable Grounding
Fault Current (kA)
Cable Length (ft)
Min Shield AWG:
-
| Shield Resistance:
-
69. MV Cable Stress Cone
Cable Voltage (kV)
Insulation Thickness (mils)
Stress Cone Length:
-
| Min Creep:
-
70. Submarine Cable Weight
Cable Dia (in)
Length (ft)
Armor Type
None
Steel Wire
Lead Sheath
Weight in Water:
-
| Air Weight:
-
71. Motor Efficiency
Input Power (kW)
Output Power (HP)
Efficiency:
-
| Losses:
-
72. Motor Torque
HP
RPM
Torque:
-
73. Motor Slip
Synchronous RPM
Actual RPM
Slip:
-
| Slip RPM:
-
74. Motor Starting Current
FLA
Motor Code Letter
B
C
D
E
F
G
H
J
K
LRA (Locked Rotor):
-
75. Motor Full Load Current (NEC Table)
HP
Voltage
208
230
460
Phase
3
1
FLA:
-
76. Motor Insulation Class Temp
Ambient Temp (°C)
Insulation Class
A
B
F
H
Max Winding Temp:
-
| Temp Rise:
-
77. VFD Sizing
Motor HP
Motor FLA
Duty
Normal
Heavy
VFD Rating:
-
| Min HP:
-
78. Motor Inrush Current
FLA
Starting Method
DOL
Star/Delta
Soft Starter
VFD
Inrush:
-
| Duration:
-
79. Motor Service Factor Amps
FLA
Service Factor
Max Continuous Amps:
-
| Overload:
-
80. Motor kW / HP Conversion
Value
Convert
HP to kW
kW to HP
Result:
-
81. Power Factor
kW
kVA
PF:
-
| kVAR:
-
82. kW to kVA
kW
Power Factor
kVA:
-
83. Line Current (3-Phase Delta)
Phase Current (A)
Connection
Delta
Wye
Line Current:
-
84. Phase Current (3-Phase)
Line Current (A)
Connection
Delta
Wye
Phase Current:
-
85. Delta-Wye Voltage Conversion
Line Voltage
Conversion
L-L to L-N
L-N to L-L
Result:
-
86. 3-Phase Power
Voltage (L-L)
Current (A)
PF
kW:
-
| kVA:
-
87. 1-Phase Power
Voltage
Current (A)
PF
kW:
-
| kVA:
-
88. Percent Impedance
Transformer kVA
Short Circuit Test V
Rated Voltage
%Z:
-
89. Load Factor
Avg Load (kW)
Peak Load (kW)
Period (hours)
Load Factor:
-
| kWh/day:
-
90. Diversity Factor
Sum of Individual Max (kW)
System Max (kW)
Diversity Factor:
-
91. Voltage Divider
Vin (V)
R1 (Ω)
R2 (Ω)
Vout:
-
| Current:
-
92. Resistor Color Code
Band 1
Brown
Red
Orange
Yellow
Green
Blue
Violet
Band 2
Black
Red
Orange
Multiplier
1
10
100
1000
10000
100000
1000000
Resistance:
-
93. LED Resistor
Supply Voltage (V)
LED Forward V (V)
LED Current (mA)
Resistor:
-
| Power:
-
94. Battery Runtime
Battery Ah
Load (W)
Battery Voltage
12
24
48
Efficiency %
Runtime:
-
95. UPS Sizing
Total Load (W)
Power Factor
Runtime (min)
UPS VA:
-
| Battery Wh:
-
96. Ohm's Law
Calculate
V = I × R
I = V / R
R = V / I
P = V × I
Input 1
Input 2
Result:
-
97. Energy Cost
Watts
Hours/Day
Rate ($/kWh)
Daily:
-
| Monthly:
-
| Yearly:
-
98. Conductor Resistance
AWG
14
12
10
8
6
4
2
1/0
Length (ft)
Temp (°C)
Resistance:
-
99. NEC Conduit Body Fill
Conductor AWG
14
12
10
8
6
Conductor Count
Conduit Size
1/2
3/4
1
Max Conductors Allowed:
-
| Status:
-
100. Electrical Unit Converter
Value
From
kW
HP
BTU/hr
kVA
Amps @240V
To
HP
kW
BTU/hr
kVA
Result:
-